12 research outputs found

    Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography.

    Get PDF
    Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR).This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients(median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (j = 0.73). To identify relevant,more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging

    Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography

    Get PDF
    Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR). This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients (median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR 4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (κ = 0.73). To identify relevant, more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging

    Round-the-clock performance of coronary CT angiography for suspected acute coronary syndrome: Results from the BEACON trial

    Get PDF
    Objective: To assess the image quality of coronary CT angiography (CCTA) for suspected acute coronary syndrome (ACS) outside office hours. Methods: Patients with symptoms suggestive of an ACS underwent CCTA at the emergency department 24 hours, 7 days a week. A total of 118 patients, of whom 89 (75 %) presented during office hours (weekdays between 07:00 and 17:00) and 29 (25 %) outside office hours (weekdays between 17:00 and 07:00, weekends and holidays) underwent CCTA. Image quality was evaluated per coronary segment by two experienced readers and graded on an ordinal scale ranging from 1 to 3. Results: There were no significant differences in acquisition parameters, beta-blocker administration or heart rate between patients presenting during office hours and outside office hours. The median quality score per patient was 30.5 [interquartile range 26.0–33.5] for patients presenting during office hours in comparison to 27.5 [19.75–32.0] for patients presenting outside office hours (p=0.043). The number of non-evaluable segments was lower for patients presenting during office hours (0 [0–1.0] vs. 1.0 [0–4.0], p=0.009). Conclusion: Image quality of CCTA outside office hours in the diagnosis of suspected ACS is diminished. Key Points: • Quality scores were higher for coronary-CTA during office hours.• There were no differences in acquisition parameters.• There was a non-significant trend towards higher heart rates outside office hours.• Coronary-CTA on the ED requires state-of-the-art scanner technology and sufficiently trained staff.• Coronary-CTA on the ED needs preparation time and optimisation o

    Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose

    No full text
    Purpose: This study aims to compare image quality, radiation dose, and the influence of the heart rate on image quality of high-pitch spiral coronary computed tomography angiography (CCTA) using 128-slice (second generation) dual-source CT (DSCT) and a 192-slice DSCT (third generation) scanner. Materials and Methods: Two consecutive cohorts of fifty patients underwent CCTA by high-pitch spiral scan mode using 128 or 192-slice DSCT. The 192-slice DSCT system has a more powerful roentgen tube (2 × 120 kW) that allows CCTA acquisition at lower tube voltages, wider longitudinal coverage for faster table speed (732 m/s), and the use of iterative reconstruction. Objective image quality was measured as the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality was evaluated using a Likert scale. Results: While the effective dose was lower with 192-slice DSCT (1.2 ± 0.5 vs. 0.6 ± 0.3 mSv; P < 0.001), the SNR (18.9 ± 4.3 vs. 11.0 ± 2.9; P < 0.001) and CNR (23.5 ± 4.8 vs. 14.3 ± 4.1; P < 0.001) were superior to 128-slice DSCT. Although patients scanned with 192-slice DSCT had a faster heart rate (59 ± 7 vs. 56 ± 6; P = 0.045), subjective image quality was scored higher (4.2 ± 0.8 vs. 3.0 ± 0.7; P < 0.001) compared to 128-slice DSCT. Conclusions: High-pitch spiral CCTA by 192-slice DSCT provides better image quality, despite a higher average heart rate, at lower radiation doses compared to 128-slice DSCT

    Coronary CT angiography derived fractional flow reserve: Methodology and evaluation of a point of care algorithm

    No full text
    Background: Recently several publications described the diagnostic value of coronary CT angiography (coronary CTA) derived fractional flow reserve (CTA-FFR). For a recently introduced on-site CTA-FFR application, detailed methodology and factors potentially affecting performance have not yet been described. Objective: To provide a methodological background for an on-site CTA-FFR application and evaluate the effect of patient and acquisition characteristics. Methods: The on-site CTA-FFR application utilized a reduced-order hybrid model applying pressure drop models within stenotic regions. In 116 patients and 203 vessels the diagnostic performance of CTA-FFR was investigated using invasive FFR measurements as a reference. The effect of several potentially relevant factors on CTA-FFR was investigated. Results: 90 vessels (44%) had a hemodynamically relevant stenosis according to invasive FFR (threshold <= 0.80). The overall vessel-based sensitivity, specificity and accuracy of CTA-FFR were 88% (CI 95%: 79 -94%), 65% (55-73%) and 75% (69-81%). The specificity was significantly lower in the presence of misalignment artifacts (25%, CI: 6-57%). A non-significant reduction in specificity from 74% (60-85%) to 48% (26-70%) was found for higher coronary artery calcium scores. Left ventricular mass, diabetes mellitus and large vessel size increased the discrepancy between invasive FFR and CTA-FFR values. Conclusions: On-site calculation of CTA-FFR can identify hemodynamically significant CAD with an overall per-vessel accuracy of 75% in comparison to invasive FFR. The diagnostic performance of CTA-FFR is negatively affected by misalignment artifacts. CTA-FFR is potentially affected by left ventricular mass, diabetes mellitus and vessel size. (C) 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved

    Integrating CT Myocardial Perfusion and CT-FFR in the Work-Up of Coronary Artery Disease

    No full text
    Adriaan Coenen, Marisa Lubbers and Koen Nieman were supported by a grant from the Dutch Heart Foundation (NHS 2014T061). Francesca Pugliese: This work forms part of the translational research portfolio of the NIHR Cardiovascular Biomedical Research Unit at Barts, which is supported and funded by the NIHR. Alexia Rossi: recipient of a Training Grant by the European Society of Cardiology (2014)
    corecore